{"id":1411,"date":"2026-11-08T08:00:00","date_gmt":"2026-11-08T08:00:00","guid":{"rendered":"https:\/\/paowogroup.com\/?p=1411"},"modified":"2026-11-08T08:00:00","modified_gmt":"2026-11-08T08:00:00","slug":"transfer-chute-liners-keeping-seams-out-of-direct-particle-impact","status":"publish","type":"post","link":"https:\/\/paowogroup.com\/pt\/transfer-chute-liners-keeping-seams-out-of-direct-particle-impact\/","title":{"rendered":"Transferir forros de calha: mantendo as costuras fora do impacto direto das part\u00edculas"},"content":{"rendered":"<div class=\"wp-block-rank-math-toc-block\" id=\"rank-math-toc\"><h2>\u00cdndice<\/h2><nav><ul><li class=\"\"><a href=\"#keeping-seams-out-of-direct-particle-impact\">Keeping Seams Out of Direct Particle Impact<\/a><\/li><li class=\"\"><a href=\"#the-inputs-that-define-transfer-chute-liners\">The inputs that define transfer chute liners<\/a><\/li><li class=\"\"><a href=\"#design-the-complete-interface-transfer-chute-liners\">Design the complete interface: transfer chute liners<\/a><\/li><li class=\"\"><a href=\"#compare-the-available-procurement-routes\">Compare as rotas de aquisi\u00e7\u00e3o dispon\u00edveis<\/a><\/li><li class=\"\"><a href=\"#qualify-a-representative-sample-or-trial-transfer-chute-liners\">Qualify a representative sample or trial: transfer chute liners<\/a><\/li><li class=\"\"><a href=\"#recognize-the-limits-and-stop-conditions\">Reconhecer os limites e as condi\u00e7\u00f5es de parada<\/a><\/li><li class=\"\"><a href=\"#build-a-complete-quotation-package\">Construa um pacote de cota\u00e7\u00e3o completo<\/a><\/li><li class=\"\"><a href=\"#discuss-the-reviewed-requirement-with-paowo\">Discuta o requisito revisado com Paowo<\/a><\/li><li class=\"\"><a href=\"#frequently-asked-questions\">Perguntas frequentes<\/a><\/li><\/ul><\/nav><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">A transfer chute receives a concentrated stream near a panel joint. For buyers reviewing transfer chute liners, the practical question is whether the offered product and its supporting evidence address this specific requirement.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This guide examines keeping seams out of direct particle impact as a defined engineering and purchasing decision. It connects the duty, interface, qualification and quotation so procurement can resolve the important questions before releasing an order.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/paowogroup.com\/wp-content\/uploads\/2026\/06\/yingyong-3.jpg\" alt=\"Pain\u00e9is de revestimento aparafusados pretos circundando uma zona de material a granel\" class=\"wp-image-307\" srcset=\"https:\/\/paowogroup.com\/wp-content\/uploads\/2026\/06\/yingyong-3.jpg 600w, https:\/\/paowogroup.com\/wp-content\/uploads\/2026\/06\/yingyong-3-300x200.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"keeping-seams-out-of-direct-particle-impact\">Keeping Seams Out of Direct Particle Impact<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">An exposed upstream edge can catch particles and accelerate local damage.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Draw the incoming stream trajectory against the panel layout and mark where it first contacts the chute. Check whether a seam or fixing sits at that point. Move or redesign the detail through the approved process if necessary. After commissioning, inspect the inlet locally rather than averaging its condition with the much larger sliding area farther downstream.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Start by separating the observed symptom from the proposed product change. Record what happens, where it happens and the operating condition in which it matters. That makes the review of transfer chute liners specific enough to support a decision, rather than a comparison of broad product descriptions.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Survey accuracy<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Before fabricating transfer chute liners for existing equipment, reconcile old drawings with the actual structure. Repairs and previous modifications can alter holes, corners and access. Record the survey basis and resolve mismatches before releasing a full set. A first panel or critical intersection template can reveal uncertainty early, when a correction is cheaper than a failed outage installation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"the-inputs-that-define-transfer-chute-liners\">The inputs that define transfer chute liners<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Record stream trajectory, impact location, flow direction, joint position. Keep the units, revision and source of each input with the inquiry. Distinguish a measured value from an estimate, and identify the person responsible for resolving any critical unknown. A supplier can review an explicit assumption; an undocumented assumption is much harder to detect.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Commissioning<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Commission transfer chute liners through the equipment owner&#x27;s approved process, checking assembly before material flow and inspecting after an initial representative exposure. Record operating conditions and panel positions. New movement, interference or blockage needs a controlled review. A successful dry fit confirms geometry but cannot establish long-term wear, flow improvement or suitability across all feed conditions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"design-the-complete-interface-transfer-chute-liners\">Design the complete interface: transfer chute liners<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Place and detail seams in relation to the actual material path.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Review transfer chute liners in the installed arrangement. Show adjoining components, the direction of movement or load, and the space needed for installation and later removal. If the interface changes, update the released drawing and acceptance basis together so the quote and the technical approval still refer to the same requirement.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Whole-system cost<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A cost comparison for transfer chute liners should include machining, installation, access, outage duration and realistic replacement frequency. A low-cost panel can be expensive in a hard-to-reach transfer point. Use recorded maintenance events and exposure rather than an invented service-life multiplier. Present estimated savings as assumptions until a representative operating history supports them.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/paowogroup.com\/wp-content\/uploads\/2026\/08\/family-chute-liners.png\" alt=\"Pain\u00e9is de revestimento aparafusados brancos dentro de uma calha de manuseio de materiais\" class=\"wp-image-1260\" srcset=\"https:\/\/paowogroup.com\/wp-content\/uploads\/2026\/08\/family-chute-liners.png 1536w, https:\/\/paowogroup.com\/wp-content\/uploads\/2026\/08\/family-chute-liners-300x200.png 300w, https:\/\/paowogroup.com\/wp-content\/uploads\/2026\/08\/family-chute-liners-1024x683.png 1024w, https:\/\/paowogroup.com\/wp-content\/uploads\/2026\/08\/family-chute-liners-768x512.png 768w, https:\/\/paowogroup.com\/wp-content\/uploads\/2026\/08\/family-chute-liners-18x12.png 18w, https:\/\/paowogroup.com\/wp-content\/uploads\/2026\/08\/family-chute-liners-600x400.png 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"compare-the-available-procurement-routes\">Compare as rotas de aquisi\u00e7\u00e3o dispon\u00edveis<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Use the comparison below to decide what must happen before purchasing transfer chute liners. The routes describe different scopes of work; they are not interchangeable offers. In this application, the controlling issue is keeping seams out of direct particle impact. An apparently cheaper route may leave that issue unresolved.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Rota<\/th><th>Quando merece revis\u00e3o<\/th><th>Evid\u00eancias necess\u00e1rias antes da libera\u00e7\u00e3o<\/th><\/tr><\/thead><tbody><tr><td>Conjunto forro uniforme<\/td><td>Potencialmente adequado quando o dever e o apoio s\u00e3o razoavelmente consistentes.<\/td><td>Verifique o caminho real do material, o suporte do painel e os detalhes da instala\u00e7\u00e3o.<\/td><\/tr><tr><td>Sistema de revestimento zoneado<\/td><td>Vale a pena rever onde o impacto deslizante e concentrado diferem.<\/td><td>Combine cada zona com um crit\u00e9rio documentado de servi\u00e7o e inspe\u00e7\u00e3o.<\/td><\/tr><tr><td>Fluxo ou redesenho de equipamentos<\/td><td>Necess\u00e1rio quando a geometria ou as condi\u00e7\u00f5es do processo dominam o problema.<\/td><td>Resolva o problema mais amplo do sistema antes de prometer uma melhoria somente no revestimento.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Packing sequence<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Package transfer chute liners by equipment zone and installation sequence where this reduces confusion. Keep hardware separated and identified, and protect functional edges during transport. Request a complete manifest that can be checked before the outage. Correct panel counts are insufficient if one special corner piece or a required fixing kit is missing.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"qualify-a-representative-sample-or-trial-transfer-chute-liners\">Qualify a representative sample or trial: transfer chute liners<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Inspect the joint after a controlled representative throughput interval.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For transfer chute liners, write the trial objective before collecting results. Record the item or sample identity, drawing revision, conditions, observations and acceptance decision. Keep a photograph or measurement record where it helps explain the outcome. If the trial covers only one part of the duty, retain the remaining questions instead of treating a limited result as full approval.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Panel boundaries<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Lay out transfer chute liners around flow direction, service access and practical handling. Module boundaries should help installation and replacement while avoiding exposed edges in severe flow. Consider the removal sequence and tool access before finalizing panel sizes. A large panel that reduces seam count can still be costly if maintenance cannot remove it through the available opening.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/paowogroup.com\/wp-content\/uploads\/2026\/06\/cp-2.jpg\" alt=\"Placas de revestimento preto empilhadas com furos de fixa\u00e7\u00e3o usinados\" class=\"wp-image-157\" srcset=\"https:\/\/paowogroup.com\/wp-content\/uploads\/2026\/06\/cp-2.jpg 800w, https:\/\/paowogroup.com\/wp-content\/uploads\/2026\/06\/cp-2-300x300.jpg 300w, https:\/\/paowogroup.com\/wp-content\/uploads\/2026\/06\/cp-2-150x150.jpg 150w, https:\/\/paowogroup.com\/wp-content\/uploads\/2026\/06\/cp-2-768x768.jpg 768w, https:\/\/paowogroup.com\/wp-content\/uploads\/2026\/06\/cp-2-600x600.jpg 600w, https:\/\/paowogroup.com\/wp-content\/uploads\/2026\/06\/cp-2-100x100.jpg 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"recognize-the-limits-and-stop-conditions\">Reconhecer os limites e as condi\u00e7\u00f5es de parada<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Edge lifting or concentrated chipping requires redesign of the impact zone.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Defina quem pode suspender a aprova\u00e7\u00e3o e quem pode autorizar uma corre\u00e7\u00e3o Preservar o item com falha, medi\u00e7\u00f5es relevantes e detalhes operacionais quando pr\u00e1tico Alterar o produto e o processo circundante simultaneamente pode dificultar o estabelecimento da causa A pr\u00f3xima a\u00e7\u00e3o deve resolver a incerteza de controle em vez de apenas repetir a compra com um tamanho nominal maior.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Articula\u00e7\u00f5es e movimento<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Joint details for transfer chute liners should account for flow and the movement permitted by the design. An upstream-facing step can collect material or expose an edge to damage. A fully constrained polymer panel may behave differently as temperature changes. Use reviewed sections and installation directions rather than leaving the fitters to decide overlaps and clearances during the shutdown.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"build-a-complete-quotation-package\">Construa um pacote de cota\u00e7\u00e3o completo<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Provide a chute section with feed direction and expected impact region.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The quotation package for transfer chute liners should identify the requested quantity, delivery destination and purchased condition, together with the relevant drawing or layout. Ask suppliers to list exclusions and deviations clearly. Compare like scope: material identity, functional dimensions, inspection, packing and any first-article work should be visible beside the unit price.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Fixing recesses<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Fasteners for transfer chute liners need a coordinated head, recess, backing and wear allowance. Metal should not become exposed in the moving material path before the defined replacement point. The recess also reduces the remaining polymer section. Review these competing requirements on a section drawing and confirm that the planned inspection can detect the controlling condition.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Thermal duty<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The specification for transfer chute liners must include normal and credible abnormal material temperatures. Grade-specific limitations and the complete assembly need review. An average operating temperature can hide an occasional hot batch or process upset. Do not assume that a tougher or thicker polymer panel solves an unsuitable thermal duty; use an appropriate alternative where the approved limits are exceeded.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"discuss-the-reviewed-requirement-with-paowo\">Discuta o requisito revisado com Paowo<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Listas Paowo <a href=\"https:\/\/paowogroup.com\/pt\/product\/uhmwpe-wear-liners\/\">Forros de desgaste UHMWPE<\/a> entre seus produtos atuais e descreve desenho - e trabalho baseado em amostra atrav\u00e9s de sua <a href=\"https:\/\/paowogroup.com\/pt\/oem-odm-custom\/\">Servi\u00e7o personalizado OEM e ODM<\/a>. Para o aplicativo discutido aqui, envie a interface espec\u00edfica e as informa\u00e7\u00f5es de servi\u00e7o antes de solicitar uma recomenda\u00e7\u00e3o final.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Voc\u00ea tamb\u00e9m pode revisar o site <a href=\"https:\/\/paowogroup.com\/pt\/mining-bulk-material-handling\/\">\u00e1rea de aplica\u00e7\u00e3o relacionada<\/a> e o artigo existente <a href=\"https:\/\/paowogroup.com\/pt\/aggregate-chute-liners\/\">Revestimentos de calhas UHMWPE para opera\u00e7\u00f5es agregadas e pedreiras<\/a> for adjoining considerations. Keep the scope of this inquiry centered on keeping seams out of direct particle impact.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Para contexto oficial, consulte <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.147\" target=\"_blank\" rel=\"noopener\">Orienta\u00e7\u00e3o da OSHA sobre controle de energia perigosa<\/a>. OSHA 1910.147 aborda o controle de energia perigosa durante a manuten\u00e7\u00e3o e manuten\u00e7\u00e3o cobertas. Utilizar os procedimentos de isolamento aplic\u00e1veis da planta para trabalhos de revestimento; esta refer\u00eancia n\u00e3o estabelece desempenho de desgaste ou fluxo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Request a review of transfer chute liners with your drawings, operating conditions, required outcome and delivery needs. Ask Paowo to identify the offered grade and specification, state unresolved assumptions and separate sample work from production scope. Use the inquiry form after the FAQ to share the requirement and request a quotation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"frequently-asked-questions\">Perguntas frequentes<\/h2>\n\n\n<div id=\"rank-math-faq\" class=\"rank-math-block\">\n<div class=\"rank-math-list\">\n<div id=\"faq-014-1\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">What is the first issue to review for transfer chute liners?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>An exposed upstream edge can catch particles and accelerate local damage. Start with the actual duty and the relevant interfaces rather than the product name alone.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-014-2\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">What information is needed to specify transfer chute liners?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Provide stream trajectory, impact location, flow direction, joint position. Include a drawing or layout showing the complete interface and identify critical unknowns before release.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-014-3\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">How should a trial of transfer chute liners be assessed?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Inspect the joint after a controlled representative throughput interval. Keep sample identity, representative conditions and the agreed acceptance decision in the trial record.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-014-4\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">When should approval of transfer chute liners be held?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Edge lifting or concentrated chipping requires redesign of the impact zone. Resolve the cause and obtain the responsible technical approval before release or continued use.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-014-5\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">What should I send Paowo when requesting transfer chute liners?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Provide a chute section with feed direction and expected impact region. Add the quantity, destination, current drawing revision and required documentation so offers can be compared on equivalent scope.<\/p>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class='fluentform ff-default fluentform_wrapper_3 ffs_default_wrap'><form data-form_id=\"3\" id=\"fluentform_3\" class=\"frm-fluent-form fluent_form_3 ff-el-form-top ff_form_instance_3_1 ff-form-loading ffs_default\" data-form_instance=\"ff_form_instance_3_1\" method=\"POST\" action=\"\" ><fieldset  style=\"border: none!important;margin: 0!important;padding: 0!important;background-color: transparent!important;box-shadow: none!important;outline: none!important; min-inline-size: 100%;\">\n                    <legend class=\"ff_screen_reader_title\" style=\"display: block; margin: 0!important;padding: 0!important;height: 0!important;text-indent: -999999px;width: 0!important;overflow:hidden;\">\u5b98\u7f51\u8be2\u76d8<\/legend>        <div\n                style=\"display: none!important; position: absolute!important; transform: translateX(1000%)!important;\"\n                class=\"ff-el-group ff-hpsf-container\"\n        >\n            <div class=\"ff-el-input--label asterisk-right\">\n                <label for=\"ff_3_item_sf\" aria-label=\"Boletim Informativo\">\n                    Boletim Informativo                <\/label>\n            <\/div>\n            <div class=\"ff-el-input--content\">\n                <input type=\"text\"\n                       name=\"item_3__fluent_sf\"\n                       class=\"ff-el-form-control\"\n                       id=\"ff_3_item_sf\"\n                \/>\n            <\/div>\n        <\/div>\n        <input type='hidden' name='__fluent_form_embded_post_id' value='1411' \/><input type=\"hidden\" id=\"_fluentform_3_fluentformnonce\" name=\"_fluentform_3_fluentformnonce\" value=\"ebfd390a96\" \/><input type=\"hidden\" name=\"_wp_http_referer\" value=\"\/pt\/wp-json\/wp\/v2\/posts\/1411\" \/><div data-name=\"ff_cn_id_1\"  class='ff-t-container ff-column-container ff_columns_total_2'><div class='ff-t-cell ff-t-column-1' style='flex-basis: 50%;'><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_input_text' id='label_ff_3_input_text' aria-label=\"Nome\">Nome<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"input_text\" class=\"ff-el-form-control\" placeholder=\"Nome\" data-name=\"input_text\" id=\"ff_3_input_text\"  aria-invalid=\"false\" aria-required=\"true\"><\/div><\/div><\/div><div class='ff-t-cell ff-t-column-2' style='flex-basis: 50%;'><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_subject' id='label_ff_3_subject' aria-label=\"Telefone\">Telefone<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"subject\" class=\"ff-el-form-control\" placeholder=\"Telefone\" data-name=\"subject\" id=\"ff_3_subject\"  aria-invalid=\"false\" aria-required=\"true\"><\/div><\/div><\/div><\/div><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_3_email' id='label_ff_3_email' aria-label=\"E-mail\">E-mail<\/label><\/div><div class='ff-el-input--content'><input type=\"email\" name=\"email\" id=\"ff_3_email\" class=\"ff-el-form-control\" placeholder=\"Endere\u00e7o de e-mail\" data-name=\"email\"  aria-invalid=\"false\" aria-required=\"true\"><\/div><\/div><div class='ff-el-group'><div class=\"ff-el-input--label asterisk-right\"><label for='ff_3_message' id='label_ff_3_message' aria-label=\"Sua Mensagem\">Sua Mensagem<\/label><\/div><div class='ff-el-input--content'><textarea aria-required=\"false\" aria-labelledby=\"label_ff_3_message\" name=\"message\" id=\"ff_3_message\" class=\"ff-el-form-control\" placeholder=\"Sua Mensagem\" rows=\"5\" cols=\"2\" data-name=\"message\" ><\/textarea><\/div><\/div><div class='ff-el-group ff-text-left ff_submit_btn_wrapper'><button type=\"submit\" class=\"ff-btn ff-btn-submit ff-btn-md ff_btn_style\"  aria-label=\"Enviar Formul\u00e1rio\">Enviar Formul\u00e1rio<\/button><\/div><\/fieldset><input type=\"hidden\" name=\"trp-form-language\" value=\"pt\"\/><\/form><div id='fluentform_3_errors' class='ff-errors-in-stack ff_form_instance_3_1 ff-form-loading_errors ff_form_instance_3_1_errors'><\/div><\/div>            <script type=\"text\/javascript\">\n                window.fluent_form_ff_form_instance_3_1 = {\"id\":\"3\",\"ajaxUrl\":\"https:\\\/\\\/paowogroup.com\\\/wp-admin\\\/admin-ajax.php\",\"settings\":{\"layout\":{\"labelPlacement\":\"top\",\"helpMessagePlacement\":\"with_label\",\"errorMessagePlacement\":\"inline\",\"cssClassName\":\"\",\"asteriskPlacement\":\"asterisk-right\"},\"restrictions\":{\"denyEmptySubmission\":{\"enabled\":false}}},\"form_instance\":\"ff_form_instance_3_1\",\"form_id_selector\":\"fluentform_3\",\"rules\":{\"input_text\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global_message\":\"This field is required\",\"global\":true}},\"subject\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}},\"email\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"},\"email\":{\"value\":true,\"message\":\"This field must contain a valid email\",\"global\":false,\"global_message\":\"This field must contain a valid email\"}},\"message\":{\"required\":{\"value\":false,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}}},\"debounce_time\":300,\"file_upload_settings\":[]};\n                            <\/script>","protected":false},"excerpt":{"rendered":"<p>Evaluate transfer chute liners for keeping seams out of direct particle impact. Review duty, fit, trial evidence and RFQ details with Paowo.<\/p>","protected":false},"author":1,"featured_media":307,"comment_status":"","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","rank_math_title":"Transfer Chute Liners: Keeping Seams Out of Direct Particle","rank_math_description":"Evaluate transfer chute liners for keeping seams out of direct particle impact. Review duty, fit, trial evidence and RFQ details with Paowo.","rank_math_canonical_url":"https:\/\/paowogroup.com\/transfer-chute-liners-keeping-seams-out-of-direct-particle-impact\/","rank_math_focus_keyword":"transfer chute liners"},"categories":[21],"tags":[],"class_list":["post-1411","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/paowogroup.com\/pt\/wp-json\/wp\/v2\/posts\/1411","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/paowogroup.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/paowogroup.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/paowogroup.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/paowogroup.com\/pt\/wp-json\/wp\/v2\/comments?post=1411"}],"version-history":[{"count":1,"href":"https:\/\/paowogroup.com\/pt\/wp-json\/wp\/v2\/posts\/1411\/revisions"}],"predecessor-version":[{"id":1564,"href":"https:\/\/paowogroup.com\/pt\/wp-json\/wp\/v2\/posts\/1411\/revisions\/1564"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/paowogroup.com\/pt\/wp-json\/wp\/v2\/media\/307"}],"wp:attachment":[{"href":"https:\/\/paowogroup.com\/pt\/wp-json\/wp\/v2\/media?parent=1411"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/paowogroup.com\/pt\/wp-json\/wp\/v2\/categories?post=1411"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/paowogroup.com\/pt\/wp-json\/wp\/v2\/tags?post=1411"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}